Test-Retest Reliability of a Novel Isokinetic Squat Device With Strength-Trained Athletes

Lee A Bridgeman, Michael R McGuigan, Nicholas D Gill, Deborah K Dulson

Research output: Contribution to journalArticle

Abstract

Bridgeman, LA, McGuigan, MR, Gill, ND, and Dulson, DK. Test-retest reliability of a novel isokinetic squat device with strength-trained athletes. J Strength Cond Res 30(11): 3261-3265, 2016-The aim of this study was to investigate the test-retest reliability of a novel multijoint isokinetic squat device. The subjects in this study were 10 strength-trained athletes. Each subject completed 3 maximal testing sessions to assess peak concentric and eccentric force (N) over a 3-week period using the Exerbotics squat device. Mean differences between eccentric and concentric force across the trials were calculated. Intraclass correlation coefficients (ICCs) and coefficients of variation (CVs) for the variables of interest were calculated using an excel reliability spreadsheet. Between trials 1 and 2 an 11.0 and 2.3% increase in mean concentric and eccentric forces, respectively, was reported. Between trials 2 and 3 a 1.35% increase in the mean concentric force production and a 1.4% increase in eccentric force production was reported. The mean concentric peak force CV and ICC across the 3 trials was 10% (7.6-15.4) and 0.95 (0.87-0.98) respectively. However, the mean eccentric peak force CV and ICC across the trials was 7.2% (5.5-11.1) and 0.90 (0.76-0.97), respectively. Based on these findings it is suggested that the Exerbotics squat device shows good test-retest reliability. Therefore practitioners and investigators may consider its use to monitor changes in concentric and eccentric peak force.

Original languageEnglish
Pages (from-to)3261-3265
Number of pages5
JournalJournal of Strength and Conditioning Research
Volume30
Issue number11
DOIs
Publication statusPublished - Nov 2016
Externally publishedYes

Fingerprint

Reproducibility of Results
Athletes
Equipment and Supplies
Research Personnel

Cite this

Bridgeman, Lee A ; McGuigan, Michael R ; Gill, Nicholas D ; Dulson, Deborah K. / Test-Retest Reliability of a Novel Isokinetic Squat Device With Strength-Trained Athletes. In: Journal of Strength and Conditioning Research. 2016 ; Vol. 30, No. 11. pp. 3261-3265.
@article{d219329b90a746f197682b82cf6943f4,
title = "Test-Retest Reliability of a Novel Isokinetic Squat Device With Strength-Trained Athletes",
abstract = "Bridgeman, LA, McGuigan, MR, Gill, ND, and Dulson, DK. Test-retest reliability of a novel isokinetic squat device with strength-trained athletes. J Strength Cond Res 30(11): 3261-3265, 2016-The aim of this study was to investigate the test-retest reliability of a novel multijoint isokinetic squat device. The subjects in this study were 10 strength-trained athletes. Each subject completed 3 maximal testing sessions to assess peak concentric and eccentric force (N) over a 3-week period using the Exerbotics squat device. Mean differences between eccentric and concentric force across the trials were calculated. Intraclass correlation coefficients (ICCs) and coefficients of variation (CVs) for the variables of interest were calculated using an excel reliability spreadsheet. Between trials 1 and 2 an 11.0 and 2.3{\%} increase in mean concentric and eccentric forces, respectively, was reported. Between trials 2 and 3 a 1.35{\%} increase in the mean concentric force production and a 1.4{\%} increase in eccentric force production was reported. The mean concentric peak force CV and ICC across the 3 trials was 10{\%} (7.6-15.4) and 0.95 (0.87-0.98) respectively. However, the mean eccentric peak force CV and ICC across the trials was 7.2{\%} (5.5-11.1) and 0.90 (0.76-0.97), respectively. Based on these findings it is suggested that the Exerbotics squat device shows good test-retest reliability. Therefore practitioners and investigators may consider its use to monitor changes in concentric and eccentric peak force.",
author = "Bridgeman, {Lee A} and McGuigan, {Michael R} and Gill, {Nicholas D} and Dulson, {Deborah K}",
year = "2016",
month = "11",
doi = "10.1519/JSC.0000000000001410",
language = "English",
volume = "30",
pages = "3261--3265",
journal = "Journal of Strength and Conditioning Research",
issn = "1064-8011",
publisher = "NSCA National Strength and Conditioning Association",
number = "11",

}

Test-Retest Reliability of a Novel Isokinetic Squat Device With Strength-Trained Athletes. / Bridgeman, Lee A; McGuigan, Michael R; Gill, Nicholas D; Dulson, Deborah K.

In: Journal of Strength and Conditioning Research, Vol. 30, No. 11, 11.2016, p. 3261-3265.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Test-Retest Reliability of a Novel Isokinetic Squat Device With Strength-Trained Athletes

AU - Bridgeman, Lee A

AU - McGuigan, Michael R

AU - Gill, Nicholas D

AU - Dulson, Deborah K

PY - 2016/11

Y1 - 2016/11

N2 - Bridgeman, LA, McGuigan, MR, Gill, ND, and Dulson, DK. Test-retest reliability of a novel isokinetic squat device with strength-trained athletes. J Strength Cond Res 30(11): 3261-3265, 2016-The aim of this study was to investigate the test-retest reliability of a novel multijoint isokinetic squat device. The subjects in this study were 10 strength-trained athletes. Each subject completed 3 maximal testing sessions to assess peak concentric and eccentric force (N) over a 3-week period using the Exerbotics squat device. Mean differences between eccentric and concentric force across the trials were calculated. Intraclass correlation coefficients (ICCs) and coefficients of variation (CVs) for the variables of interest were calculated using an excel reliability spreadsheet. Between trials 1 and 2 an 11.0 and 2.3% increase in mean concentric and eccentric forces, respectively, was reported. Between trials 2 and 3 a 1.35% increase in the mean concentric force production and a 1.4% increase in eccentric force production was reported. The mean concentric peak force CV and ICC across the 3 trials was 10% (7.6-15.4) and 0.95 (0.87-0.98) respectively. However, the mean eccentric peak force CV and ICC across the trials was 7.2% (5.5-11.1) and 0.90 (0.76-0.97), respectively. Based on these findings it is suggested that the Exerbotics squat device shows good test-retest reliability. Therefore practitioners and investigators may consider its use to monitor changes in concentric and eccentric peak force.

AB - Bridgeman, LA, McGuigan, MR, Gill, ND, and Dulson, DK. Test-retest reliability of a novel isokinetic squat device with strength-trained athletes. J Strength Cond Res 30(11): 3261-3265, 2016-The aim of this study was to investigate the test-retest reliability of a novel multijoint isokinetic squat device. The subjects in this study were 10 strength-trained athletes. Each subject completed 3 maximal testing sessions to assess peak concentric and eccentric force (N) over a 3-week period using the Exerbotics squat device. Mean differences between eccentric and concentric force across the trials were calculated. Intraclass correlation coefficients (ICCs) and coefficients of variation (CVs) for the variables of interest were calculated using an excel reliability spreadsheet. Between trials 1 and 2 an 11.0 and 2.3% increase in mean concentric and eccentric forces, respectively, was reported. Between trials 2 and 3 a 1.35% increase in the mean concentric force production and a 1.4% increase in eccentric force production was reported. The mean concentric peak force CV and ICC across the 3 trials was 10% (7.6-15.4) and 0.95 (0.87-0.98) respectively. However, the mean eccentric peak force CV and ICC across the trials was 7.2% (5.5-11.1) and 0.90 (0.76-0.97), respectively. Based on these findings it is suggested that the Exerbotics squat device shows good test-retest reliability. Therefore practitioners and investigators may consider its use to monitor changes in concentric and eccentric peak force.

U2 - 10.1519/JSC.0000000000001410

DO - 10.1519/JSC.0000000000001410

M3 - Article

VL - 30

SP - 3261

EP - 3265

JO - Journal of Strength and Conditioning Research

JF - Journal of Strength and Conditioning Research

SN - 1064-8011

IS - 11

ER -