Test-Retest Reliability of a Novel Isokinetic Squat Device With Strength-Trained Athletes

Lee A Bridgeman, Michael R McGuigan, Nicholas D Gill, Deborah K Dulson

Research output: Contribution to journalArticlepeer-review

Abstract

The aim of this study was to investigate the test-retest reliability of a novel multijoint isokinetic squat device. The subjects in this study were 10 strength-trained athletes. Each subject completed 3 maximal testing sessions to assess peak concentric and eccentric force (N) over a 3-week period using the Exerbotics squat device. Mean differences between eccentric and concentric force across the trials were calculated. Intraclass correlation coefficients (ICCs) and coefficients of variation (CVs) for the variables of interest were calculated using an excel reliability spreadsheet. Between trials 1 and 2 an 11.0 and 2.3% increase in mean concentric and eccentric forces, respectively, was reported. Between trials 2 and 3 a 1.35% increase in the mean concentric force production and a 1.4% increase in eccentric force production was reported. The mean concentric peak force CV and ICC across the 3 trials was 10% (7.6-15.4) and 0.95 (0.87-0.98) respectively. However, the mean eccentric peak force CV and ICC across the trials was 7.2% (5.5-11.1) and 0.90 (0.76-0.97), respectively. Based on these findings it is suggested that the Exerbotics squat device shows good test-retest reliability. Therefore practitioners and investigators may consider its use to monitor changes in concentric and eccentric peak force.

Original languageEnglish
Pages (from-to)3261-3265
Number of pages5
JournalJournal of Strength and Conditioning Research
Volume30
Issue number11
DOIs
Publication statusPublished - Nov 2016
Externally publishedYes

Fingerprint

Dive into the research topics of 'Test-Retest Reliability of a Novel Isokinetic Squat Device With Strength-Trained Athletes'. Together they form a unique fingerprint.

Cite this