Determining the reliability of a custom built seated stadiometry set-up for measuring spinal height in participants with chronic low back pain

James Steele, Stewart Bruce-Low, Dave Smith, David Jessop, Neil Osborne

Research output: Contribution to journalArticle

Abstract

Indirect measurement of disc hydration can be obtained through measures of spinal height using stadiometry. However, specialised stadiometers for this are often custom-built and expensive. Generic wall-mounted stadiometers alternatively are common in clinics and laboratories. This study examined the reliability of a custom set-up utilising a wall-mounted stadiometer for measurement of spinal height using custom built wall mounted postural rods. Twelve participants with non-specific chronic low back pain (CLBP; females n = 5, males n = 7) underwent measurement of spinal height on three separate consecutive days at the same time of day where 10 measurements were taken at 20 s intervals. Comparisons were made using repeated measures analysis of variance for 'trial' and 'gender'. There were no significant effects by trial or interaction effects of trial x gender. Intra-individual absolute standard error of measurement (SEM) was calculated for spinal height using the first of the 10 measures, the average of 10 measures, the total shrinkage, and the rate of shrinkage across the 10 measures examined as the slope of the curve when a linear regression was fitted. SEMs were 3.1 mm, 2.8 mm, 2.6 mm and 0.212, respectively. Absence of significant differences between trials and the reported SEMs suggests this custom set-up for measuring spinal height changes is suitable use as an outcome measure in either research or clinical practice in participants with CLBP.
Original languageEnglish
Pages (from-to)203-208
JournalApplied Ergonomics
Publication statusPublished - 2016

Fingerprint

Low Back Pain
pain
Linear Models
Analysis of Variance
Outcome Assessment (Health Care)
Research
Scanning electron microscopy
gender
Analysis of variance (ANOVA)
analysis of variance
Linear regression
Hydration
regression
interaction

Cite this

@article{5bc72cc646ba4d1792d1c2df408e2580,
title = "Determining the reliability of a custom built seated stadiometry set-up for measuring spinal height in participants with chronic low back pain",
abstract = "Indirect measurement of disc hydration can be obtained through measures of spinal height using stadiometry. However, specialised stadiometers for this are often custom-built and expensive. Generic wall-mounted stadiometers alternatively are common in clinics and laboratories. This study examined the reliability of a custom set-up utilising a wall-mounted stadiometer for measurement of spinal height using custom built wall mounted postural rods. Twelve participants with non-specific chronic low back pain (CLBP; females n = 5, males n = 7) underwent measurement of spinal height on three separate consecutive days at the same time of day where 10 measurements were taken at 20 s intervals. Comparisons were made using repeated measures analysis of variance for 'trial' and 'gender'. There were no significant effects by trial or interaction effects of trial x gender. Intra-individual absolute standard error of measurement (SEM) was calculated for spinal height using the first of the 10 measures, the average of 10 measures, the total shrinkage, and the rate of shrinkage across the 10 measures examined as the slope of the curve when a linear regression was fitted. SEMs were 3.1 mm, 2.8 mm, 2.6 mm and 0.212, respectively. Absence of significant differences between trials and the reported SEMs suggests this custom set-up for measuring spinal height changes is suitable use as an outcome measure in either research or clinical practice in participants with CLBP.",
author = "James Steele and Stewart Bruce-Low and Dave Smith and David Jessop and Neil Osborne",
year = "2016",
language = "English",
pages = "203--208",
journal = "Applied Ergonomics",
issn = "0003-6870",
publisher = "Elsevier Limited",

}

Determining the reliability of a custom built seated stadiometry set-up for measuring spinal height in participants with chronic low back pain. / Steele, James; Bruce-Low, Stewart; Smith, Dave; Jessop, David; Osborne, Neil.

In: Applied Ergonomics, 2016, p. 203-208.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Determining the reliability of a custom built seated stadiometry set-up for measuring spinal height in participants with chronic low back pain

AU - Steele, James

AU - Bruce-Low, Stewart

AU - Smith, Dave

AU - Jessop, David

AU - Osborne, Neil

PY - 2016

Y1 - 2016

N2 - Indirect measurement of disc hydration can be obtained through measures of spinal height using stadiometry. However, specialised stadiometers for this are often custom-built and expensive. Generic wall-mounted stadiometers alternatively are common in clinics and laboratories. This study examined the reliability of a custom set-up utilising a wall-mounted stadiometer for measurement of spinal height using custom built wall mounted postural rods. Twelve participants with non-specific chronic low back pain (CLBP; females n = 5, males n = 7) underwent measurement of spinal height on three separate consecutive days at the same time of day where 10 measurements were taken at 20 s intervals. Comparisons were made using repeated measures analysis of variance for 'trial' and 'gender'. There were no significant effects by trial or interaction effects of trial x gender. Intra-individual absolute standard error of measurement (SEM) was calculated for spinal height using the first of the 10 measures, the average of 10 measures, the total shrinkage, and the rate of shrinkage across the 10 measures examined as the slope of the curve when a linear regression was fitted. SEMs were 3.1 mm, 2.8 mm, 2.6 mm and 0.212, respectively. Absence of significant differences between trials and the reported SEMs suggests this custom set-up for measuring spinal height changes is suitable use as an outcome measure in either research or clinical practice in participants with CLBP.

AB - Indirect measurement of disc hydration can be obtained through measures of spinal height using stadiometry. However, specialised stadiometers for this are often custom-built and expensive. Generic wall-mounted stadiometers alternatively are common in clinics and laboratories. This study examined the reliability of a custom set-up utilising a wall-mounted stadiometer for measurement of spinal height using custom built wall mounted postural rods. Twelve participants with non-specific chronic low back pain (CLBP; females n = 5, males n = 7) underwent measurement of spinal height on three separate consecutive days at the same time of day where 10 measurements were taken at 20 s intervals. Comparisons were made using repeated measures analysis of variance for 'trial' and 'gender'. There were no significant effects by trial or interaction effects of trial x gender. Intra-individual absolute standard error of measurement (SEM) was calculated for spinal height using the first of the 10 measures, the average of 10 measures, the total shrinkage, and the rate of shrinkage across the 10 measures examined as the slope of the curve when a linear regression was fitted. SEMs were 3.1 mm, 2.8 mm, 2.6 mm and 0.212, respectively. Absence of significant differences between trials and the reported SEMs suggests this custom set-up for measuring spinal height changes is suitable use as an outcome measure in either research or clinical practice in participants with CLBP.